Mersen’s HP10J photovoltaic (PV) fuse series is designed specifically for DC Recombiner Boxes in the protection of 1000VDC photovoltaic systems. Its robust construction makes it ideal for continuous temperature and current cycling withstand adding to system longevity. The 1000VDC rated HP10J designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen’s HelioProtection® fuse line.
Mersen’s HP10J photovoltaic (PV) fuse series is designed specifically for DC Recombiner Boxes in the protection of 1000VDC photovoltaic systems. Its robust construction makes it ideal for continuous temperature and current cycling withstand adding to system longevity. The 1000VDC rated HP10J designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen’s HelioProtection® fuse line.
Product data sheets
- DS-HP10J-HelioProtection-Fuses-Photovoltaic-Mersenpdf - 717.48 KB 
Compliance
- COM-RoHS-RS000129-HP10J-Mersenpdf - 141.95 KB 
- COM-REACH-RE000129-HP10J-Mersenpdf - 146.97 KB 
Key features & benefits
- UL Listed to standard 2579 – Photovoltaic Fuses 
- Smallest available footprint in the industry 
- Enlarged mounting holes 
- Low fault current interrupting capability 
- Durable construction for enhanced system longevity 
- Temperature cycle withstand capability 
- Guaranteed operation at temperature extremes 
- Blown fuse indicator options available (EI option) 
- 200A to 400A available in NH3 mounting 
Applications
- Re-combiner box (sub-combiner, array combiner, master combiner) applications 
- Inverter DC input 
- Battery charge controllers 
| Frequency (Hz) | 50/60 Hz | 
| Amperage Range | 70 to 600 A | 
| Fuse Class | Photovoltaic | 
| Speed/Characteristic | gPV | 
| UL Category Code | JFGA | 
| Reach Compliant | Yes | 
| Max Operating Temp. | 80 °C | 
| Max Storage Temp. | 80 °C | 
| Min Storage Temp. | -25 °C | 
| Harmonized System | 853610 | 
| UL File Number | File E333668 | 
Reference Finder
Scroll
| Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight | 
|---|---|---|---|---|---|
| HP10J100 See product | 100A | - | - | No | 0.1134kg | 
| HP10J100EI See product | 100A | - | - | Yes | 0.1225kg | 
| HP10J125 See product | 125A | - | - | No | 0.1134kg | 
| HP10J125EI See product | 125A | - | - | Yes | 0.1225kg | 
| HP10J160 See product | 160A | - | - | No | 0.1134kg | 
| HP10J160EI See product | 160A | - | - | Yes | 0.1225kg | 
| HP10J200 See product | 200A | - | - | No | 0.1134kg | 
| HP10J200EI See product | 200A | - | - | Yes | 0.1225kg | 
| HP10J250 See product | 250A | - | - | No | 0.7938kg | 
| HP10J250EI See product | 250A | - | - | Yes | 0.8391kg | 