EVpack-fuse MEV50, 500 VDC Max., L/R less than or equal 2.5ms, 60 - 800A
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
Product data sheets
Brochures and Flyers
- Mersen-Solutions-for-EV-HEV-e-Mobility-ENpdf - 5.21 MB 
Compliance
- COM-CE-ROHS-declaration-CN0002-MEV50Apdf - 157.17 KB 
- COM-UKCA-declaration-CN0002-MEV50Apdf - 157.1 KB 
Key features & benefits
- Design for DC applications 
- Low watt losses 
- High cycling performance 
- Full coverage of battery module voltage and current 
- Ultra compact size 
- Current Ratings (In): 5 to 800A 
- Interrupting Rating (IR) for MEV55C: 20kA @550VDC, L/R ≤ 1ms 
- Interrupting Rating (IR) for MEV50A: 30kA @500VDC, L/R ≤ 2.5ms 
Applications
- EV/HEV 
- Battery pack protection 
- Battery Disconnect Unit (BDU) 
- Battery Management Systm (BMS) 
- Battery Junction Box for auxiliaries 
- On-Board Charging 
| Amperage Range | 60…800 A | 
| Speed/Characteristic | aR | 
| CE Conformity | true | 
| Reach Compliant | Yes | 
Reference Finder
Scroll
| Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight | 
|---|---|---|---|---|---|
| MEV50A100-20G See product | 100A | 20G | - | No | 0.041kg | 
| MEV50A100-25G See product | 100A | 25G | - | No | 0.075kg | 
| MEV50A125-20G See product | 125A | 20G | - | No | 0.041kg | 
| MEV50A125-25G See product | 125A | 25G | - | No | 0.075kg | 
| MEV50A150-20G See product | 150A | 20G | - | No | 0.041kg | 
| MEV50A150-25G See product | 150A | 25G | - | No | 0.075kg | 
| MEV50A150-30G See product | 150A | 30G | - | No | 0.1kg | 
| MEV50A200-25G See product | 200A | 25G | - | No | 0.075kg | 
| MEV50A200-30G See product | 200A | 30G | - | No | 0.1kg | 
| MEV50A250-25G See product | 250A | 25G | - | No | 0.075kg | 